Hidden fire extinguishers may look sleek, but OSHA and NFPA require clear identification and accessible placement, no matter how polished the design.

80 points•josephcsible•about 2 months ago•33 comments•

33 comments

no-name-hereabout 2 months ago
Weird writing:

1. “Reportedly, an Apple retail or office installation has been circulating” - but they then include a tweet as their apparent source that explicitly says it’s the 5th Ave store. So why say it might be an Apple office instead?

2. Maybe they are so wishy-washy about it because they aren’t confident it’s real, but if that’s the case, then writing a lengthy article calling something “stupidity” that you can’t even confidently state occurred…

3. “Reportedly, an Apple retail or office installation has been circulating” has a hyperlink across multiple words so you’d think it would be their source, but no it’s to the Apple homepage.

dannywabout 2 months ago
It’s a LLM generated article, and from the sentence style, I think a GPT. It looks like it’s been put through a “humaniser” or had less copy editing.

Just about all of gadgetreview.com is LLM writing these days.

Gigachadabout 2 months ago
This article is just a popular tweet that has been converted in to an ad filled article. Probably all done by AI.

For all we know even the original video from the tweet is ai generated.

samtheprogramabout 2 months ago
> putting occupants at risk in seconds

Yeah, uh, I totally agree with you and won't be reading the rest.

jareklupinskiabout 2 months ago
dont you just love being an occupant
colmmaccabout 2 months ago
The "Steve Jobs" movie features a made-up subplot about Jobs insisting that the Fire Exit Safety signs be turned off to achieve "absolute blackout" in a theater. They very reasonably point out that no fire Marshall would approve it. I'm surprised for that reason, especially in midtown Manhattan. I've seen a fire marshall do a full inspection of a Broadway show and they were very thorough. This store is just a few blocks from there.
flowerladabout 2 months ago
Let’s face it, the flat UI is stupidity when it comes to anything. This is not an issue exclusive to fire extinguishers.

https://www.nngroup.com/articles/flat-design/

pseudohadamardabout 2 months ago
Flat minimal-contrast UI is one of those things that's nearly universally loathed by everyone except UI designers but that has bafflingly persisted in the marketplace for over a decade now. I'm sure there's a nice psychology-study article waiting to be written on the reason for this.

Compare with the equivalent in architecture, https://www.worksinprogress.news/p/do-people-prefer-traditio..., in particular the two photos halfway down where non-architects overwhelmingly preferred the reasonably-pleasant design in the first photo while architects preferred Cell Block D in the second.

AlotOfReadingabout 2 months ago
I wonder if this could have been made trivially compliant by using a transparent window with a sticker, like they do for AED machines.
exmadscientistabout 2 months ago
It doesn't even have to be transparent! (I think.) Big red "FIRE" letters and either a visible handle to open or very obvious instructions would probably be acceptable.
usef-about 2 months ago
Maybe I'm misremembering, but do most luxury stores have fire extinguishers visible to customers (as opposed to staff)? I don't remember seeing them
dannywabout 2 months ago
Usually luxury stores have sprinkler protection, availability of fire hose reels, etc.

In Australia this would not comply with our fire code. Putting it behind a cabinet is fine; but it must have visible signs that can be seen from 20m away with a 20/20 eyesight (assuming no obstruction etc).

This applies to all portable extinguishers; even if it’s additional ones you’ve added beyond what’s required. The idea and intent is simple: train people and first responders to locate portable fire extinguishers by the sign.

jlduggerabout 2 months ago
I don't recall Coach bags catching fire[1] though.

[1]: https://appleinsider.com/articles/18/01/09/iphone-battery-fi...

walrus01about 2 months ago
I wonder if fire safety code (either in NYC, NY State, or nationally) has caught up with some sort of specific regulation for additional fire safety when you have N amount of watt-hours of lithium ion battery storage contained in X amount of square feet of retail space with Y type of fire suppression/detection systems. The same general concept as why you can't take above a 99Wh battery on an airplane as an individual unit, but extended to something like the Apple Store or the laptop display section in a Best Buy.

The closest thing I've seen is a big push from the NYC government to get people to stop charging their sketchy ebike/scooter battery packs indoors in hallways and apartments, which has caused more than a few fires.

https://www.google.com/search?client=firefox-b-d&q=nyc+ebike...

usef-about 2 months ago
They don't use fire extinguishers for lithium battery fires though (as the article mentioned: submerging it in special sand).

I wonder if it would actually be a negative if a member of the public grabbed a visible extinguisher during a battery fire?

Read the full thread on Hacker News →